Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Front Oncol ; 13: 1166035, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37416528

RESUMO

Background: This study evaluates the diagnostic accuracy of ultrasound-guided fine needle aspiration (US-FNA) and core needle biopsy (US-CNB) for detecting axillary lymph nodes in women with breast cancer. Methods: Eligible studies and pertinent literature resources were identified in Cochrane, PubMed, Embase, CNKI, VIP, and Wanfang databases using subject-specific keywords. Study outcomes were tested for heterogeneity, and meta-analyses were performed to estimate sensitivity, specificity, and diagnostic odds ratios (DORs). The summary receiver operating characteristic (SROC) curve analysis was also performed. Results: A total of 22 studies involving 3,548 patients were included to evaluate the diagnostic accuracy of US-FNA and 11 studies involving 758 patients were included to evaluate the diagnostic accuracy of US-CNB in identifying axillary lymph nodes in women with breast cancer. The accuracy of US-FNA in identifying suspicious axillary lymph nodes was as follows: overall sensitivity, 79% (95% CI: 73%-84%); global specificity, 96% (95% CI: 92%-98%); overall positive likelihood ratio, 18.55 (95% CI: 10.53-32.69); overall negative likelihood ratio, 0.22 (95% CI: 0.17-0.28); DOR, 71.68 (95% CI: 37.19-138.12); and the area under the SROC curve, 0.94 (95% CI: 0.92-0.96). The accuracy of US-CNB in identifying suspicious axillary lymph nodes was as follows: overall sensitivity, 85% (95% CI: 81%-89%); global specificity, 93% (95% CI: 87%-96%); overall positive likelihood ratio, 11.88 (95% CI: 6.56-21.50); overall negative likelihood ratio, 0.16 (95% CI: 0.12-0.21); overall DOR, 66.83 (95% CI: 33.28-134.21), and the area under SROC curve 0.96 (95% CI: 0.94-0.97). Conclusions: The results indicate that both US-FNA and US-CNB have high accuracy for suspicious axillary lymph nodes.

2.
Ultrasound Med Biol ; 49(8): 1830-1836, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37270353

RESUMO

OBJECTIVE: The arteriovenous fistula (AVF) is an essential vascular access for hemodialysis patients. AVF stenosis may occur at sites with abnormal wall shear stress (WSS) and oscillatory shear index (OSI), which are caused by the complex flow in the AVF. At present, an effective method for rapid determination of the WSS and OSI of the AVF is lacking. The objective of this study was to apply an ultrasound-based method for determination of the WSS and OSI to explore the risk sites of the AVF. METHODS: In this study, the ultrasound vector flow imaging technique V Flow was applied to measure the WSS and OSI at four different regions of the AVF to detect and analyze the risk sites: (i) anastomosis region, (ii) curved region, (iii) proximal vein and (iv) distal vein. Twenty-one patients were included in this study. The relative residence time was calculated based on the measured WSS and OSI. RESULTS: The curved region had the lowest WSS; the anastomosis region had a significantly higher OSI (p < 0.05) compared with the venous regions, and the curved region had a significantly higher RRT (p < 0.05) compared with the proximal vein region. CONCLUSION: V Flow is a feasible tool for studying WSS variations in AVF. The possible risk site in the AVF may be located in the anastomosis and curved regions, where the latter could present a higher risk for AVF stenosis.


Assuntos
Fístula Arteriovenosa , Veias , Humanos , Velocidade do Fluxo Sanguíneo , Constrição Patológica , Fístula Arteriovenosa/diagnóstico por imagem , Diálise Renal , Estresse Mecânico , Hemodinâmica
3.
Front Cardiovasc Med ; 10: 1282597, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38173818

RESUMO

Abdominal vascular compression syndrome (AVCS) is caused by the compression of abdominal blood vessels by adjacent structures or the compression of abdominal organs by neighboring blood vessels. Such compressions can result in a variety of clinical symptoms. They are not commonly seen in ultrasound practices, and their presence may have been underrecognized and underdiagnosed. This article reviews the clinical features, ultrasound characteristics, and diagnostic criteria of four types of AVCS, namely, celiac artery compression syndrome, renal vein compression syndrome, iliac vein compression syndrome, and superior mesenteric artery syndrome to increase awareness of these conditions among ultrasound practitioners. The ultrasound criteria for AVCS are primarily based on studies with small sample sizes, and therefore, it is important to exercise caution if these criteria are used.

4.
Clin Invest Med ; 45(4): E25-32, 2022 12 31.
Artigo em Inglês | MEDLINE | ID: mdl-36586104

RESUMO

PURPOSE: To investigate the value of anteroposterior-to-transverse ratio (ATR) and the effect on features of nodules in ultrasound (US) diagnosis of thyroid nodules in different locations.  Methods: The nodules were divided into three groups according to the different nodule location: isthmus group; upper and lower poles of bilobed thyroid group; and the middle of the bilobed thyroid group. The diameters of the nodules were recorded, and ATR of the nodule was calculated on the transverse and longitudinal sections. The transverse and the longitudinal sections of ATR of thyroid nodules in different groups were compared.  Result: The transverse section of ATR was significantly different among the three groups (p = 0.001). In addition, there are significant differences in many US features among three groups, including nodule composition, thyroid parenchyma, morphology, echogenicity, shape, calcifications, vascularity, nodule ACR TI-RADS and histopathologic (all p < 0.05). In the group of upper and lower poles of bilobed thyroid, significant difference was found between the transverse and the longitudinal section of ATR (p = 0.019). The cut-off values of transverse section and longitudinal section of ATR were 0.967 and 0.750, respectively.  Conclusion: The transverse section of ATR at different location of thyroid may be a predictor for malignancy with clinical diagnostic significance.


Assuntos
Neoplasias da Glândula Tireoide , Nódulo da Glândula Tireoide , Humanos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/patologia , Estudos Retrospectivos , Ultrassonografia
5.
Eur J Med Res ; 27(1): 217, 2022 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-36307894

RESUMO

INTRODUCTION: To explore how to measure LAPEq accurately and quantitatively, that is, the left atrial pressure (LAP) measured and calculated by equation method using mitral regurgitation spectrum. METHODS: The mitral regurgitation spectrum, pulmonary arteriolar wedge pressure (PAWP) and invasive arterial systolic pressure of radial artery of 28 patients were collected simultaneously, including 3 patients with rheumatic heart disease, 15 patients with mitral valve prolapse and 10 patients with coronary artery bypass grafting, patients with moderate or above aortic stenosis were excluded. LAPBp (Doppler sphygmomanometer method), LAPEq (Equation method) and LAPC (Catheter method) were measured synchronously, and the measurement results of the three methods were compared and analyzed. A special intelligent Doppler spectrum analysis software was self-designed to accurately measure LAPEq. This study had been approved by the ethics committee of the Northern Theater General Hospital (K-2019-17), and applied for clinical trial (No. Chictr 190023812). RESULTS: It was found that there was no significant statistical difference between the measurement results of LAPC and LAPEq (t = 0.954, P = 0.348), and significant correlation between the two methods [r = 0.908(0.844, 0.964), P < 0.001]. Although the measurement results of LAPC and LAPBP are consistent in the condition of non-severe eccentric mitral regurgitation, there are significant differences in the overall case and weak correlation between the two methods [r = 0.210, (-0.101, 0.510), P = 0.090]. In MVP patients with P1 or P3 prolapse, the peak pressure difference of MR was underestimated due to the serious eccentricity of MR, which affected the accuracy of LAPBP measurement. CONCLUSIONS: It was shown that there is a good correlation between LAPEq and LAPC, which verifies that the non-invasive and direct quantitative measurement of left atrial pressure based on mitral regurgitation spectrum is feasible and has a good application prospect.


Assuntos
Insuficiência da Valva Mitral , Humanos , Pressão Atrial , Catéteres , Ecocardiografia Doppler/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Pressão Propulsora Pulmonar
6.
Vasc Med ; 27(6): 542-550, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36000474

RESUMO

INTRODUCTION: This study aims to evaluate changes in the arterial spectral Doppler waveform in a canine artery stenosis model. METHODS: Canine femoral artery stenosis models were established in 12 beagle dogs. Doppler waveforms were recorded in the femoral artery preoperatively and postoperatively in the femoral artery and at the ankle after formation of a 50%, 70%, and 90% stenosis or occlusion. Major descriptors for arterial Doppler waveform were used to analyse waveforms. RESULTS: The proportion of multiphasic waveforms proximal to a moderate stenosis decreased compared to normal baseline, although the difference was not statistically significant, whereas the decreases at the stenosis, distal to the stenosis, and at the ankle were significant (p < 0.05). The decreases in arteries with a more severe stenosis or occlusion were significant at all locations (p < 0.05). The proportion of high resistive waveforms decreased significantly at the ankle in the arteries with a moderate stenosis (50%) (p = 0.002), but the decreases proximal to, at, and distal to the stenosis were not significant. The decreases were significant at all locations in the arteries with a more severe stenosis (p < 0.05). The decrease was significant at the ankle in the arteries with an occlusion (p < 0.001) but not significant pre, at, and post an occlusion. CONCLUSIONS: Phasicity and resistance of Doppler waveforms alter in canine femoral arteries with a stenosis. Phasicity change seems more sensitive in response to an arterial stenosis than resistance change. Additional information on arterial resistance could be obtained using end-diastolic ratios, resistive indices, and potentially end-systolic notch velocity measurements.


Assuntos
Artéria Femoral , Humanos , Animais , Cães , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Constrição Patológica
8.
Ann Transl Med ; 10(2): 105, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35282091

RESUMO

Background: This study sought to investigate the accuracy of estimating left atrial pressure (LAP) using the continuous wave Doppler spectrum of mitral regurgitation. Methods: Dog models of left atrial hypertension with mitral regurgitation were established with disposable biopsy forceps and the injection of melamine formaldehyde resin microsphere suspension. A total of 40 models of left atrial hypertension with different hemodynamic statuses were established by injecting either esmolol or dobutamine in which the spectrums of mitral regurgitation were clear and the regurgitation velocity exceeded 3.5 m/s. The continuous wave Doppler spectrums of mitral regurgitation were recorded and analyzed to estimate left atrial pressure (LAPECHO). The mean left atrial pressure (LAPC-MEAN), the isovolumic diastolic left atrial pressure (LAPC-IVRT), the maximum left atrial pressure (LAPC-MAX), and the minimum left atrial pressure (LAPC-MIN) were also measured using the catheter method in the same cardiac cycle. Results: The LAPECHO (mean ± standard deviation; 11.77±4.36 mmHg) was correlated with the LAPC-MEAN (11.51±4.77 mmHg; r=0.887, P=0.000), but the difference was not statistically significant (P=0.459). The LAPECHO was correlated with the LAPC-IVRT (12.16±4.72 mmHg; r=0.883, P=0.000), but the difference was not statistically significant (P=0.271). There was a correlation between the LAPC- MEAN and the LAPC-IVRT (r=0.987, P=0.000), and the difference was statistically significant (P=0.000). Conclusions: This study suggests that the ultrasound evaluation of LAP correlates well with LAP measured using the gold standard catheter method, and is a simple, convenient, non-invasive method to quantitatively estimate LAP. This method is promising, but further large-scale animal experiments and clinical studies need to be conducted.

9.
Front Cardiovasc Med ; 9: 829825, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35282375

RESUMO

Objective: To investigate the value of Vector Flow Imaging (V Flow) in the assessment of post-stenotic turbulence in the canine arterial stenosis model. Materials and Methods: Canine femoral artery stenosis models were established using ameroid constrictors in 12 beagle dogs. 50% and then 70% femoral artery stenoses were confirmed by selective femoral artery angiography. V Flow was used to measure femoral artery flow turbulence index (Tur) preoperatively as a baseline. After establishing of a 50% and then 70% stenoses, the Tur indices were recorded in the femoral artery at 1, 3, 5, 7, 9, 11, 13, 15, 17, and 19 mm distal to the stenosis. Results: Baseline Tur indices of normal canine femoral arteries were <1% in 11 of 12 cases (91.7%). Distal to a 50% stenosis, the Tur index (>1%) was recorded in 83.3-100% cases between 1 and 9 mm, 41.7-58.3% between 11 and 17 mm, and 16.7% at 19 mm. For a 70% stenosis, the Tur index (>1%) occurred in 81.8-100% cases between 1 and 17 mm distal to the stenosis, and 63.6% at 19 mm. The Tur index peaked around 7 mm or 2.3 times of the initial vessel diameter (3 mm) downstream for a 50% stenosis and 11 mm or 3.7 times of vessel diameter downstream for a 70% stenosis. Conclusion: V Flow with Tur index measurement adds quantitative information of post-stenotic turbulence when assessing an arterial stenosis with ultrasound. Tur index of 1% seems a useful threshold for assessment of flow turbulence in this small sample study. Further studies with larger sample size are needed to evaluate the value of V Flow in clinical applications.

10.
J Geriatr Cardiol ; 18(4): 252-260, 2021 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-33995504

RESUMO

OBJECTIVE: To investigate a new noninvasive method for calculating left ventricular diastolic time constant (Tau) through a continuous-wave aortic regurgitation Doppler spectrum. METHODS: According to ultrasound guidance, twenty-four animal models (beagles) of aortic regurgitation and acute ischemic left ventricular diastolic dysfunction were created. The left ventricular diastolic function was manipulated with dobutamine or esmolol and fifty-nine hemodynamic stages were achieved. Raw audio signals of the continuous-wave Doppler spectra were collected, and new aortic regurgitation Doppler spectra were built after reprocessing by a personal computer. The updating time of the spectral line was 0.3 ms. The new Doppler spectra contour line was automated using MATLAB (MATrix LABoratory, MathWorks, Natick, MA, USA), and two time intervals, (t2-t1) and (t3-t1) were measured on the ascending branch of the aortic regurgitation Doppler spectrum. Then, the two time intervals were substituted into Bai's equations, and Doppler-derived Tau (Tau-D) was resolved and compared with catheter-derived Tau (Tau-c). RESULTS: There is no significant difference between Tau-D and Tau-c (45.95 ± 16.90 ms and 46.81 ± 17.31 ms, respectively; P > 0.05). Correlation analysis between Tau-c and Tau-D suggested a strong positive relationship ( r = 0.97, P = 0.000). A Bland-Altman plot of Tau-c and Tau-D revealed fair agreement. CONCLUSIONS: This new calculation method is simple, convenient, and shows a strong positive relationship and fair agreement with the catheter method.

11.
J Int Med Res ; 49(3): 300060521997737, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33719686

RESUMO

Hepatic venous gas (HVG) is a very rare ultrasonic finding, and it is defined as abnormal accumulation of gas in the hepatic venous system. Various diseases can cause HVG, and femoral venous catheter is the most common cause. We, herein, present the case of a 79-year-old female patient with HVG that was caused by spontaneous rupture of a Klebsiella pneumoniae liver abscess. This was first found by bedside ultrasonography. On the basis of the blood culture results, imipenem-cilastatin and cefoperazone sulbactam were administered and the effect was acceptable. After 41 days of antibacterial and symptomatic treatment in the hospital, the patient had recovered well and was discharged. All of the previous reports on HVG have been summarized by thoroughly reviewing the previous published work. Overall, this is the first patient with HVG in association with spontaneous rupture of a K. pneumoniae liver abscess, and it might provide insights for future studies regarding the treatment of this disease.


Assuntos
Infecções por Klebsiella , Abscesso Hepático , Idoso , Feminino , Humanos , Infecções por Klebsiella/complicações , Infecções por Klebsiella/diagnóstico por imagem , Infecções por Klebsiella/tratamento farmacológico , Klebsiella pneumoniae , Abscesso Hepático/complicações , Abscesso Hepático/diagnóstico por imagem , Abscesso Hepático/tratamento farmacológico , Ruptura Espontânea , Ultrassonografia
12.
Front Cardiovasc Med ; 7: 584274, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33195470

RESUMO

Background: Non-invasive Doppler waveform (DW) analysis is a widely adopted method for detecting and evaluating lower extremity peripheral artery disease (PAD). Previous investigations have reported that broad heterogeneity in the description of Doppler waveforms is reduced by using a classification method. The reliability of arterial Doppler classification, however, is unknown. Purpose: The purpose of this study is to assess the reliability of a 4-category arterial DW classification method among Chinese sonographers. Methods: During a national ultrasound conference in China attendees were invited to classify thirty arterial Doppler waveforms. After viewing a 4-category (triphasic, biphasic, monophasic, and other) arterial Doppler waveform descriptor presentation, attendees were asked to classify 15 continuous wave (CW) and 15 pulsed wave (PW) Doppler waveforms. Their responses were recorded via mobile phone and the reliability of this 4-category classification was estimated by Fleiss' Kappa inter-rater statistical analysis. Results: One hundred and seventy-eight attendees participated in the analysis. The Kappa coefficient of Fleiss (κ) for all attendees was 0.522 (p < 0.005) with 95% confidence interval (CI): 0.520-0.523. The reliability of the waveform descriptor triphasic was the highest (κ = 0.621, p < 0.005), and other was the lowest (κ = 0.341, p < 0.005). Conclusion: The inter-rater reliability of a 4-category arterial Doppler waveform classification by Chinese sonographers is considered weak (κ = 0.522, CI95%: 0.520-0.523, p < 0.005). This study reinforces the importance of assessing DW classification reliability and the development of DW descriptors that are more accurately predictive of clinical hemodynamic events.

13.
Exp Ther Med ; 20(6): 136, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33082868

RESUMO

Atherosclerosis is a cardiovascular disease that is pathologically associated with the growth of atherosclerotic plaques and vascular vulnerability. Intravascular ultrasound (IVUS) has been used to evaluate and treat cardiovascular diseases. Accumulating evidence has demonstrated that Gd2O3-doped nanoparticles contrast can be applied for the diagnosis of human diseases. In the present study, eplerenone (EPL), a mineralocorticoid receptor antagonist, was first doped with Gd2O3 nanoparticles (Gd2O3-EPL), following which its diagnostic efficacy for use in IVUS measurements (Gd2O3-EPL-IVUS) was evaluated for patients suspected with atherosclerosis. Gd2O3-EPL-IVUS presented with higher accuracy and sensitivity compared with IVUS in diagnosing 188 patients with suspected atherosclerosis. Gd2O3-EPL-IVUS exhibited stronger signals associated with plaque morphology compared with aloe IVUS for patients with atherosclerosis. In addition, Gd2O3-EPL-IVUS application resulted in clearer arterial plaque images compared with IVUS by binding mineralocorticoid receptors. Atherosclerosis was subsequently confirmed in all patients using computerized tomography-coronary angiography. Gd2O3-EPL-IVUS showed more accuracy in measuring vessel size, plaque burden and minimal lumen area compared with IVUS analysis alone. In conclusion, these outcomes suggest that Gd2O3-EPL-IVUS is a reliable tool for the evaluation of coronary lesions in patients with atherosclerosis.

14.
Endocrine ; 70(2): 256-279, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32827126

RESUMO

Thyroid nodules are very common all over the world, and China is no exception. Ultrasound plays an important role in determining the risk stratification of thyroid nodules, which is critical for clinical management of thyroid nodules. For the past few years, many versions of TIRADS (Thyroid Imaging Reporting and Data System) have been put forward by several institutions with the aim to identify whether nodules require fine-needle biopsy or ultrasound follow-up. However, no version of TIRADS has been widely adopted worldwide till date. In China, as many as ten versions of TIRADS have been used in different hospitals nationwide, causing a lot of confusion. With the support of the Superficial Organ and Vascular Ultrasound Group of the Society of Ultrasound in Medicine of the Chinese Medical Association, the Chinese-TIRADS that is in line with China's national conditions and medical status was established based on literature review, expert consensus, and multicenter data provided by the Chinese Artificial Intelligence Alliance for Thyroid and Breast Ultrasound.


Assuntos
Neoplasias da Glândula Tireoide , Nódulo da Glândula Tireoide , Inteligência Artificial , China , Humanos , Estudos Retrospectivos , Medição de Risco , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/epidemiologia , Nódulo da Glândula Tireoide/diagnóstico por imagem , Ultrassonografia
16.
Cancer Manag Res ; 10: 4447-4458, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30349377

RESUMO

PURPOSE: This study aimed to investigate the value of shear wave elastography (SWE) for characterization of breast masses in a Chinese population. PATIENTS AND METHODS: Two thousand two hundred seventy-three women consented to be prospectively enrolled for the characterization of breast masses with ultrasound and SWE. Breast masses were known from symptoms, palpability, and/or previous imaging screening with mammography and/or ultrasound. Correlation of SWE qualitative and quantitative features with malignancy risk and impact on diagnostic performance of combining SWE features were assessed, and the Breast Imaging Reporting and Data System (BI-RADS) scoring was calculated using histopathology as reference. RESULTS: Data of 2,262 masses (median size: 13 mm; range: 1.3-50) from 2,262 patients (median age: 43 years; range: 18-91) were investigated, of which 752 (33.3%) were malignant. Sensitivity and specificity of BI-RADS diagnosis were 97.5% (733/752) and 54.8% (827/1,510), respectively. By logistic regression, the combination of maximum elasticity (E max) measurements with BI-RADS assessments increased the area under the receiver operating characteristic curve from 0.908 (95% CI: 0.896-0.920) to 0.954 (95% CI: 0.944-0.962). Using E max of 30 kPa or lower to selectively downgrade BI-RADS 4a masses to follow-up, and E max of 160 kPa or higher to selectively upgrade BI-RADS 3 lesions to biopsy, specificity significantly increased from 54.8% (827/1,510) to 66.1% (998/1,510) (P<0.001) while sensitivity decreased nonsignificantly from 97.5% (733/752) to 96.9% (729/752) (P=0.2891). Positive predictive value for biopsy recommendation increased from 51.7% (733/1,417) to 58.7% (729/1,241) (P<0.001). CONCLUSION: Adding SWE maximum stiffness to BI-RADS 3 and BI-RADS 4a breast masses in a Chinese population increased significantly the specificity of breast ultrasonography, without significant change in sensitivity.

17.
Ultrasound Med Biol ; 44(8): 1778-1785, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29735313

RESUMO

The left ventricular diastolic time constant (Tau) cannot be practically measured non-invasively. Thus, the aim of this study was to investigate a new method for the evaluation of Tau using continuous-wave (CW) Doppler in dogs with mitral regurgitation. Guided by ultrasound, we created 12 beagle models of mitral regurgitation and acute ischemic left ventricular diastolic dysfunction. Raw audio signals of the CW Doppler spectra were collected, and new mitral regurgitation Doppler spectra were observed after computer re-processing. The new Doppler spectra contour line was constructed using MATLAB (Version R2009), and two time intervals, t1-t2 and t1-t3, were measured on the descending branch of the mitral regurgitation Doppler spectrum and were substituted into Bai's equation group. The Doppler-derived Tau (Tau-d) was resolved and compared with the simultaneous catheter-derived Tau (Tau-c). No significant difference (p > 0.05) between Tau-d (49.33 ± 18.79 ms) and Tau-c (48.76 ± 17.60 ms) was found. A correlation analysis between Tau-d and Tau-c suggested a strong positive relationship (r = 0.85, p = 0.000). Bland-Altman plots of Tau-d and Tau-c revealed fair agreement. Compared with previous non-invasive approaches, this method is simpler and more accurate. There is a strong positive relationship and fair agreement between Tau-d and Tau-c.


Assuntos
Ecocardiografia Doppler/métodos , Ventrículos do Coração/fisiopatologia , Processamento de Imagem Assistida por Computador/métodos , Insuficiência da Valva Mitral/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Animais , Velocidade do Fluxo Sanguíneo , Diástole , Modelos Animais de Doenças , Cães , Ventrículos do Coração/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Tempo , Disfunção Ventricular Esquerda/diagnóstico por imagem
18.
BMC Nephrol ; 18(1): 265, 2017 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-28789641

RESUMO

BACKGROUND: To evaluate the effect of perfusion status on elasticity measurements of different compartments in the kidney using shear wave elastography (SWE) both in vivo and ex vivo. METHODS: Thirty-two rabbit kidneys were used to observe the elasticity variation caused by renal artery stenosis and vein ligation in vivo, and six beagle kidneys were studied ex vivo to explore the effect of renal perfusion on elasticity. Supersonic SWE was applied to quantify the elasticity values of different renal compartments (cortex, medulla and sinus). Additionally, histopathological examination was performed to explore the possible mechanisms. RESULTS: The elasticity of the cortex was higher than that of the medulla, and the elasticity of the sinus was lowest among the compartments in native kidneys. The Young's modulus (YM) of the cortex, medulla and sinus increased gradually as the duration of renal vein ligation increased, from 16.34 ± 1.01 kPa to 55.06 ± 5.61 kPa, 13.71 ± 1.16 kPa to 39.63 ± 2.91 kPa, and 12.61 ± 0.84 kPa to 29.30 ± 2.04 kPa, respectively. In contrast, the YM of the three compartments respectively decreased with progressive artery stenosis, from 16.34 ± 1.83 kPa to 11.21 ± 1.79 kPa, 13.31 ± 1.67 kPa to 8.07 ± 1.37 kPa, and 12.78 ± 2.66 kPa to 6.72 ± 0.95 kPa. Artery perfusion was the main factor influencing elasticity in ex vivo. The cortical elasticity was more prone to change with renal perfusion both in vivo and ex vivo. Histopathological examination showed progressive changes in the structure and content of the three compartments, consistent with the elasticity variation. CONCLUSIONS: Both the complex structure/anisotropy and the perfusion of the kidney obviously influence the evaluation of renal elasticity. The measurement of SWE should be performed at a specific location along a certain angle or direction, and renal perfusion status should also be taken into account to ensure reproducible detection.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Rim/diagnóstico por imagem , Perfusão/métodos , Obstrução da Artéria Renal/diagnóstico por imagem , Obstrução da Artéria Renal/terapia , Animais , Cães , Feminino , Rim/irrigação sanguínea , Coelhos , Distribuição Aleatória
19.
PLoS One ; 12(6): e0179103, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28614362

RESUMO

BACKGROUND: We aimed to observe the relationship between the pathological components of a deep venous thrombus (DVT), which was divided into three parts, and the findings on quantitative ultrasonic shear wave elastography (SWE) to increase the accuracy of thrombus staging in a rabbit model. METHODS: A flow stenosis-induced vein thrombosis model was used, and the thrombus was divided into three parts (head, body and tail), which were associated with corresponding observation points. Elasticity was quantified in vivo using SWE over a 2-week period. A quantitative pathologic image analysis (QPIA) was performed to obtain the relative percentages of the components of the main clots. RESULTS: DVT maturity occurred at 2 weeks, and the elasticity of the whole thrombus and the three parts (head, body and tail) showed an increasing trend, with the Young's modulus values varying from 2.36 ± 0.41 kPa to 13.24 ± 1.71 kPa; 2.01 ± 0.28 kPa to 13.29 ± 1.48 kPa; 3.27 ± 0.57 kPa to 15.91 ± 2.05 kPa; and 1.79 ± 0.36 kPa to 10.51 ± 1.61 kPa, respectively. Significant increases occurred on different days for the different parts: the head showed significant increases on days 4 and 6; the body showed significant increases on days 4 and 7; and the tail showed significant increases on days 3 and 6. The QPIA showed that the thrombus composition changed dynamically as the thrombus matured, with the fibrin and calcium salt deposition gradually increasing and the red blood cells (RBCs) and platelet trabecula gradually decreasing. Significant changes were observed on days 4 and 7, which may represent the transition points for acute, sub-acute and chronic thrombi. Significant heterogeneity was observed between and within the thrombi. CONCLUSIONS: Variations in the thrombus components were generally consistent between the SWE and QPIA. Days 4 and 7 after thrombus induction may represent the transition points for acute, sub-acute and chronic thrombi in rabbit models. A dynamic examination of the same part of the thrombus may be helpful for improving the sensitivity and reproducibility of SWE for DVT diagnosis and staging.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/patologia , Animais , Modelos Animais de Doenças , Módulo de Elasticidade , Coelhos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Som , Ondas Ultrassônicas
20.
Nan Fang Yi Ke Da Xue Xue Bao ; 37(5): 683-686, 2017 05 20.
Artigo em Chinês | MEDLINE | ID: mdl-28539295

RESUMO

OBJECTIVE: To investigate the correlation between Young's modulus of the thyroid tissue measured by in shear wave elastography (SWE) and the clinical manifestations of Hashimoto's thyroiditis in different stages. METHODS: A total of 104 patients with the clinical diagnosis of Hashimoto's thyroiditis were enrolled in this study, including 26 with hyperthyroidism, 29 with normal thyroid function, 27 with subclinical hypothyroidism, 22 with clinical hypothyroidism, with 50 healthy volunteers serving as the healthy control group. All the subjects underwent SWE to obtain the Young's modulus value of the thyroid tissue. Univariate analysis of variance was used to compare the Young's modulus among the groups, and Pearson correlation analysis was used to analyze the correlation between the Young's modulus of the thyroid tissue and serum levels of thyroid microsomal antibody (TMAb) and thyroid globulin antibody (TGAb). RESULTS: In the 4 groups of patients, the Young's modulus increased significantly in the order of hyperthyroidism group, normal thyroid function group, subclinical hypothyroidism group and clinical hypothyroidism group (F=60.983, P<0.01). The Young's modulus was significantly lower in hyperthyroidism group than in the other 3 groups (P<0.05), and was significantly lower in normal thyroid function group than in subclinical hypothyroidism group and clinical hypothyroidism group (P<0.05). CONCLUSION: The Young's modulus of the thyroid tissue measured by shear wave elastography is related with the clinical manifestations of Hashimoto's thyroiditis in different stages, but the relevance needs to be further confirmed by multi-center, randomized, controlled studies involving a larger sample size.


Assuntos
Técnicas de Imagem por Elasticidade , Doença de Hashimoto/diagnóstico por imagem , Hipotireoidismo/diagnóstico por imagem , Estudos de Casos e Controles , Módulo de Elasticidade , Humanos , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...